£849.00 £1,018.80 (Inc. VAT)
KANE900 PLUS Combustion Analyser
Kit contents:
Features
The KANE900 PLUS handheld analyser is easy to use for domestic and industrial boiler flue gas measurement and analysis.
It operates on all boiler types and can display 8 parameters simultaneously showing measurements and calculations of boiler efficiency and pollution.
Measures O2, flue and nett temperature and calculates CO2, boiler efficiency, excess air and losses.
CO is measured with a hydrogen compensated sensor for increased accuracy.
It also measures CO and calculates CO/CO2 ratio – €˜The Poison Index€™ – to give complete readings for effective boiler analysis and safety.
Measures NO and calculates NOx
.
Big character display
IR printer link… printed header can be customised
Large memory to store results for easy transfer to PC
Long life battery recharged in situ
Technical Data | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Parameter | Resolution | Accuracy | Range | ||||||||||||||||||||
Temp Measurement | |||||||||||||||||||||||
Flue Temperature | 0.1°C/F | +2.0°C +0.3% reading | 0-1200°C/32 -2200°F with suitable probe |
||||||||||||||||||||
Inlet Temperature | 0.1°C/F | +1°C +0.3% reading | 0-50°C/32-122°F | ||||||||||||||||||||
Pressure (optional) | 0.1mbar | +2% of full scale | +150mbar to -150mbar | ||||||||||||||||||||
Gas Measurement *1 | |||||||||||||||||||||||
Oxygen | 0.1% | +0.2% | 0-25% | ||||||||||||||||||||
Carbon Monoxide (standard H compensated) |
1ppm | +20ppm<400ppm +5% <5000ppm +10% >5000ppm |
0-10,000ppm, | ||||||||||||||||||||
Carbon Monoxide, (high range) |
0.01% | +5% reading from 0.1% to 10% |
0-10% | ||||||||||||||||||||
Nitric Oxide (standard) |
1ppm | +5ppm <100ppm*1 +5% >100ppm |
0-5000ppm | ||||||||||||||||||||
Nitrogen Oxide (low range) |
1ppm | +2ppm <30ppm+5ppm >30ppm | 0-1000ppm | ||||||||||||||||||||
Nitrogen Dioxide | 1ppm | +5ppm <100ppm +10ppm <5000ppm +10% >500ppm |
0-100ppm | ||||||||||||||||||||
Sulphur Dioxide | 1ppm | +5ppm <100ppm +5% >100ppm |
0-500ppm | ||||||||||||||||||||
Calculations | |||||||||||||||||||||||
Carbon Dioxide*2 | 0.1% | +0.3% reading | 0-99.9% | ||||||||||||||||||||
Losses | 0.1% | +1.0% reading | 0-99.9% | ||||||||||||||||||||
Efficiency | 0.1% | +1.0% reading | 0-99.9% | ||||||||||||||||||||
Excess Air | 0.1% | +0.2% | 0-2885.0% | ||||||||||||||||||||
Temp (Nett) | 1.0°C/F | +2°C +0.3% reading | 0-600°C/32-1112°F | ||||||||||||||||||||
CO/CO2 ratio | 0.0001 | +0.0001 | 0-0.9999 | ||||||||||||||||||||
Poison Index | 0.01% | +0.01 | 0-99.99 |
*1 Using dry gases at STP
*2 Calculated
Technical Data | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pre-programmed Fuels | Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas. | ||||||||||||||||||||||
Dimensions Weight Handset Probe |
……………….. 1kg 220mm x 55mm x 120mm L240mm x Dia8mm with 285mm long stainless steel shaft, type K thermocouple and 1.5m long neoprene hose |
||||||||||||||||||||||
Ambient Operating Range | -5°C to +50°C/10% to 90% RH non condensing | ||||||||||||||||||||||
Power Supply (battery charger) | Input: 110Vac/220 Vac nominal Output: 12 Vac off load |
||||||||||||||||||||||
Battery Life | 6 hours from full charge |
Optional Extras:– Please call or email with your requirements
Sinclair and Campbell is a leading supplier of Digital Temperature Measurement and Monitoring Instruments to the Food Processing and Catering industries.
© 2022 Sinclair Campbell | Hosted & Managed by RocketWP
Registered Office: SINCLAIR & CAMPBELL,
CLACHAN HOUSE, ROSNEATH, HELENSBURGH, SCOTLAND UK, G84 0QR