N2013 Temperature and Humidity Data Logger

The Temperature and Humidity Data Logger (N2013) records both temperature and humidity and is ideally suited to healthcare and building management applications.

  • Temperature Range: -20°C to +60°C / -4°F to +140°F
  • Humidity Range:  0 to 97% RH non-condensing
  • Battery Life: Up to 5 Years
  • Warranty: 2 Years

 


 

The Temperature and Humidity Data Logger (N2013) records both temperature and humidity and is ideally suited to healthcare and building management applications.

Many products must be stored within specific temperature and humidity ranges, and the N2013 allows you to record both. Especially relevant in a healthcare environment, the data generated by the N2013 is also ideal for a range of other building operations requirements, such as building heating and cooling systems.

Designed to be a practical and reliable instrument, the N2013 has a two year warranty, a battery life of up to 5 years, and is sealed to IP67 standards.

For general use for HACCP and other quality systems, our EVSW software is available as a free download. For other duties, such as compliance with 21CFR part 11, please upgrade your software to EVSW Pro.

 


Technical Specifications

Name Value
Sensor Types Temperature: Thermistor, Humidity: Capacitive
Temperature Measurement/Operating Range -20°C to +60°C / -4°F to +140°F
Humidity Measurement Range Humidity 0 to 97% RH non-condensing
Scales Temperature °C and °F, Humidity RH or DP
Display Resolution Temperature 0.1°, Humidity 0.1% RH
System Accuracy Temperature °C -20°C to +50°C ±0.5°C, +50°C to +60°C ±1°C
System Accuracy Temperature °F -4°F to +122°F ±1°F, +122°F to +140°F ±2°F (typical)
System Accuracy Humidity -20°C to +60°C ±3% RH, -4°F to +140°F ±3% RH
Memory Communications Via infra red interface – 1 channel 16000 samples, 2 channels 8000 samples
Download Time 3 minutes for 10,000 readings (typical)
Logging Frequency Programmable between 1 second and 99 hours
Internal Sensor Response Time T90 = 15 to 30 minutes in ambient air
Ambient Storage -40°C to +70°C / -40°F to +158°F
Compatibility Software Windows™ based software for Windows XP or Vista
Battery Type 1 x AA size 3.6V replaceable lithium battery
Battery Life Up to 5 years
Case Material ABS
Environmental Protection IP67 BS EN 60529 IEC 529
LED Indication Red = Alarm, Green = Logger Active
Dimensions Length (including fixing lug) 88mm / 3.5ins, Width 80mm / 3.1ins, Depth 35mm / 1.4ins
Warranty 2 Years

 


 