Water Activity HP23-AW-A-SET-40

Set consists of:

    • Handheld instrument: HP23-AW-A
    • Measurement probe: HC2-AW
    • Sample holder: WP-40
    • Disposable sample container (13 pc.): PS-40
    • Humidity standard 10 %rh: EA10-SCS
    • Humidity standard 35 %rh: EA35-SCS
    • Humidity standard 50 %rh: EA50-SCS
    • Humidity standard 80 %rh: EA80-SCS
    • Case: AC1124

The HygroPalm AW sets are the perfect solution for on-site measurements.
They are supplied in a tough, lightweight ABS carry case and include
everything needed for measurement and calibration.

Technical Data
HYGROPALM – HP23-AW-A – PORTABLE WATER ACTIVITY ANALYZER

Applications

The HygroPalm HP23-AW-A offers the perfect solution for on-site water activity measurements to confirm product stability and indicate shelf life.

The HP23-AW-A is suitable as a mobile laboratory unit. Equal to the HygroLab C1 the HP23-AW-A is perfect as a portable analyzer with two probe inputs for any suitable HC2 probe.

The HP23-AW-A can also be used in conjunction with HW4-P-QUICK-Vx.

Portable and convenient

Handheld instrument specially configured to suit the water activity user.
It includes many of the advanced features of the HygroLab C1, but in a convenient portable configuration.medicines, horticulture, agriculture, etc.

Features

    • 2 input channels for HC2 station probes or HC2 insertion probes can be connected for measurement of water activity, relative humidity and temperature.
    • AW Quick function for fast measurement results (typically 4-5 minutes).
    • Audible alarm to indicate completed measurement.
    • Saves up to 10’000 data records with %rh, °C, date and time.
    • Battery charging function.

 

Technical Data
RANGE OF APPLICATION -10€¦60 °C (14€¦140 °F) / 0€¦1 Aw / 0€¦100 %RH
POWER SUPPLY 9 V battery or USB/ mains adapter via mini USB
CALCULATIONS All psychrometric calculations available
CURRENT CONSUMPTION Max. 20 mA (backlight ON)
LCD 3-line alphanumeric with trend indicators
MEASUREMENT INTERVAL 1 s, 10 s, 1 min, 10 min
NUMBER OF PROBE INPUTS 1
PARAMETERS SHOWN Aw, % RH, °C, °F
PROBE CONNECTIONS 2 HygroClip2 or analog input 0€¦3.2 VDC
(power supply for analog probe: 5 VDC)
START-UP TIME 3s.
ACOUSTICAL ALARM (BEEPER) No
BATTERY INDICATOR Yes
CLOCK Real time clock provides a time
stamp for every measurement
MEMORY SIZE Capture mode: 8 x 250 values / Logging mode:
10,000 values
HW4 COMPATIBLE Yes, for all HW4 versions
PROBE ADJUSTMENT Single or multiple point for
relative humidity & temperature.
One or two point temperature
AW-QUICK MODE Yes
AW QUICK FUNCTION Integrated and via HW4 software
HW4-P-QUICK-Vx (in shipment included)
SOFTWARE UPDATE With internet and HW4 software
COMMUNICATION INTERFACES Mini USB
ENCLOSURE MATERIAL ABS
IP PROTECTION RATING IP30
SERVICE INTERFACE Mini USB
FDA / GAMP FDA 21 CFR part 11 / GAMP5
E / EMC CONFORM EMC 2008/108/EG
WEIGHT 200g

HC2-AW – AW PROBE

Applications

For water activity measurements in bulk materials such as flour, grain, spices, etc.
For solid and pasty products such as meat, sausage as well as oils, fats, etc.

Features

    • Measurement range: 0¦1 aw (0¦100 %rh), -40¦85 °C.
    • On/Off switch.
    • UART interface for direct connection to a PC.
    • Power supply via UART interface.
    • Adjusted at 23 °C and 10, 35, 80 %rh.
Technical Data
ACCURACY AT 23 ±5 °C ± 0.008 aw / 0.8 %rh / ±0.1 K
PROBE TYPE Measurement probe with UART interface
FOR USE WITH HygroLab C1, HP23-AW-A
RANGE OF APPLICATION -40¦85 °C (-40¦185 °F) / 0¦100 %RH
POWER SUPPLY Via display instruments
LONG-TERM STABILITY <1 %rh / year
HUMIDITY SENSOR HYGROMER® WA-1 / Pt-100, 1/3 DIN Class B
TEMPERATURE DEPENDENCE 0.001 K/K, 0.0002 aw/K
FILTER CARTRIDGE Wire mesh filter with 20¦25¼m pore size
RESPONSE TIME T 63 <20 sec.
PSYCHROMETRIC CALCULATIONS Dew or frost point
MEASUREMENT INTERVAL 1s
START-UP TIME 1.5s
AW-QUICK MODE Yes
COMMUNICATION INTERFACES UART
IP PROTECTION RATING IP20
MATERIAL Stainless steel, aluminum
FDA / GAMP FDA 21 CFR part 11 / GAMP5
CE / EMC CONFORM EMC 2008/108/EG
DIMENSIONS ø 68 x 60 mm

WP-40 : Sample holder 40 mm

The stainless steel sample holders were developed specifically for the water activity probes HC2-AW(-USB).
The sample holder provides excellent sample containment and optimum temperature stability.

Technical Data
FOR USE WITH PS14 / PS40
MATERIAL V2A steel
WEIGHT 1250g

PS-40 : Disposable sample containers 40 mm

Application

The disposable sample containers ensure the optimum sample volume is introduced into the WP-40 or WP-40TH sample holders. They prevent the sample holders from coming into direct contact with the product being tested,
thereby preventing soiling or cross contamination. The sample containers also provide a convenient means of collecting and storing samples.

Technical Data
FOR USE WITH WP-40 / WP-40TH
UNIT 100 pc.
WEIGHT 1250g

AC1124 : Carry case AW

Features

Cutouts for :

    • 1x HygroPalm HP23-A or HP23-AW-A
    • 1x water activity measurement probe HC2-AW
    • 1x sample holder WP-40 or WP-14-S
    • 4x ampoules (humidity standard)
    • 1x set textile pads
    • 1x 9 V battery
    • 13x Sample containers PS-14 or 6x PS-40
    • 1x instruction manual

Dimensions: 395 x 300 x 105 mm (outer)