£460.00 £552.00 (Inc. VAT)
HiTemp140-PT Semi-flexible Probe Extreme Temperature Data Logger
Product Details
HiTemp140-PT-1 has a 1.7″ sensor tip at the end of a 24″ mineral insulated cable run. This cable and sensor will collect precise (+/-0.1°C) data in the harshest of environments. The semi-flexible probe is ideally suited to product and air temperature verification studies. A carefully configured semi flexible probe can be coiled, bent or angled in any direction and will stay in that position throughout the validation exercise.
Configure a single HiTemp140-PT-1 using the IFC400 interface or multiple data loggers with the IFC406 multiplexer. Stainless steel, submersible IP68 construction enables the operation in any environment between -40°C and +140°C (with no time limit) or -200°C to +250°C for a limited time, using the TSK shield and +350°C using the ThermoVault Max barrier.
Once the validation exercise has been concluded, wait for the data loggers to cool down or warm up and insert them back into the interface. Using MT4 software and workflows to automatically download and save data before generating customised reports and performing analytical functions, including;
Benefits
Suitable for use in autoclaves
Compatible with thermal shield for use in extreme temperatures
21 CFR Part 11 Compliant
Precise temperature data logging
Batch configuration with multiplexer
Compatible with the HiTemp140 range of products and accessories which encompass the demand for reliability and high performance at reasonable prices.
Requires: IFC400 or IFC406 interface along with free issued MT4 software
Specification
Technical Data | |
---|---|
Manufacturer | MadgeTech |
Parameter | Temperature |
Usage Type | Multiple |
Sensor | Internal |
Channels | 1 |
Sensor Type | 1.7″ x 0.125″ RTD probe with 24″ mineral insulated probe cable |
Memory | 32767 readings |
Sample rate | 1 reading a second to 1 reading a day |
Range | -200°C to +260°C |
Accuracy | ±0.1°C |
Resolution | >±0.01°C |
Material | 316 Stainless Steel |
Power | User replacement battery |
Battery life | 365 days |
Dimensions | Data logger 1.9″ x 0.97″ |
Environment | IP68 |
Operating Conditions | -40°C to +140°C |
Operating Conditions | With Shield -200°C to +250°C |