£616.00 £739.20 (Inc. VAT)
Testo 570 – Digital Refrigeration Manifold
4-way-valve block, internal data memory, integrated vacuum measurement, 3 temperature probe connections, 40 refrigerants stored
Your toolcase is probably heavy, and filled with many useful helpers for your daily work. In the future, the new testo 570 will replace several of these tools. Because it is the robust expert for all imaginable measurements on a refrigeration system or heat pump with one instrument. Whether for pressure, temperature or current, you benefit from the extensive analysis possibilities and numerous technical features for all measurement tasks on a system. The testo 570-1 set contains one clamp probe, a calibration protocol and batteries.
The digital manifold testo 570 offers you all you need for your work on refrigeration systems and heat pumps. The internal data store of the testo 570 replaces manual work steps, thanks to the clear and easily understood documentation option of a measurement. Carry out long-term measurements or record data in real time, and present them graphically. The easy operation of testo 570 makes this possible. Apart from this, errors can be found and rectified more quickly in cases of malfunction. Manual documentation is a thing of the past. Measurement results can be traced, and reports called up, at any time.
Technical Data | |
---|---|
Storage temperature | -20 to +60 °C |
Operating temperature | -20 to +50 °C |
Battery life | 40 h (wthout illumination) |
Weight | approx. 1200g (without batteries) |
Dimensions | 280 x 135 x 75 mm |
Pressure media | HCFC, CFC, N, CO2, H2O |
Probe Connections | 3 x plug-in (NTC) |
Meas. range | -50 to +150 °C |
Accuracy | (at 22 °C) ±0.5°C (± 1 digit) |
Resolution | 0.1 °C / 0.1 °F |
Meas. range | (rel.) |
Meas. Range | 1 bar to 0 bar |
Accuracy | (at 22 °C) 1 % fs |
Resolution | 1mbar/ 1hPa/ 0.5Torr/ 0.5.5inH2O/ 100Pa/ 500Micron |
Low Pressure | 50/50 bar (rel) |
Accuracy | (at 22 °C) 0.5% fs (±1 digit) |
Resolution | 0.01 bar / 0.1 psi |
Overload | LP/HP: 52 bar |
Connections | 3 x 7/16€œ UNF + 1 x 5/8€œ UNF |
Printer | IR printer |
Data store in instrument | Record up to 999 h measurement values |
Optional software | EasyKool |
Refrigerants in instrument | R12, R22, R123, R134a, R227, R290, R401A, R401B, R402A, R402B, R404A,R406A, R407A, R407C, R408A, R409A,R410A, R411A, R413A,R414B, R416A,R417A, R420A, R421A, R421B, R422A,R422B, R422D, R424A, R427A, R434A,R437A, R438A, R502, R503, R507,R600, R600a, R718 (H2O), R744 (only in the permitted range up to 40 bar), R1234yf |
Sinclair and Campbell is a leading supplier of Digital Temperature Measurement and Monitoring Instruments to the Food Processing and Catering industries.
© 2022 Sinclair Campbell | Hosted & Managed by RocketWP
Registered Office: SINCLAIR & CAMPBELL,
CLACHAN HOUSE, ROSNEATH, HELENSBURGH, SCOTLAND UK, G84 0QR