Search our store

£629.00 £754.80 (Inc. VAT)

Product Description

Testo 327-1 – Flue Gas Analyser (advanced kit)

Includes
Rech. battery and calibration protocol,
Testo printer,
Flue Gas Probe (180mm X 6mm diameter),
FREE Air / Immersion Probe
Carry case

Description

testo 327-1 is your introductory instrument to flue gas analysis. It measures combustion efficiency, °C, O2, CO2, CO and flue draught. The strong LED background light in the 4 line display guarantees an easy-to-read display even if lighting conditions are unfavourable. The analyser stands out on account of its easy menu navigation and ergonomic housing as well as its durability.

    • Easy menu navigation

 

    • 4 line segment display

 

    • LED display light

 

    • Easy IR printout

 

    • Built-in condensate trap

 

    • TÃœV By RgG 253 acc. to 1. BImSchV

 

    • EN 50379 Part 2 for O2, °C, hPa

 

    • EN 50379 Part 3 for CO

 

    • Small Li-ion rechargeable battery (1200 mA, lifetime of 5 h) can be recharged inside or outside instrument

 

    • Fast probe connection using single probe plug

 

    • Ambient CO measurement using flue gas probe

 

    • O2 dual wall measurement (can be stored)

 

    • Separate AT temperature measurement

 

    • Undiluted CO measurement (can be stored)

 

    • Draught measurement

 

    • 6-8 fuels (country-specific (e.g. UK=6))

 

    • IP 40

 

 

 

 

Technical Data
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Battery life > 5 h
Weight Approx. 500 g
Dimensions 216 x 68 x 47 mm

 

 

Probe Technical Data
Probe – Type K Meas. Range -40 to +600 °C
Accuracy ±0,5 °C (0.0 to +99.9 °C)
±0,5 % of mv (100 to +600 °C)
Resolution 0.1 °C
Probe – Draught sensor Meas. Range ±40 hPa
Accuracy ±0.02 hPa (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5% of mv (+3.01 to +40 hPa)
Probe – Exhaust gas loss measurement Meas. Range 0 to 99.9%
Resolution 0.1 %
Probe – Electrochemical sensor Meas. Range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)
±5% of mv (401 to 1000 ppm)
±10% of mv (1001 to 4000 ppm)
Resolution 1 ppm
Probe – Electrochemical sensor Meas. Range 0 to 21 Vol. %
Accuracy ±0.2 Vol. %
Resolution 0.1 Vol. %
Probe – Efficiency calculated Meas. Range 0 to 120%
Resolution 0.1%
Probe – CO2-determination 0 to CO2 max
Accuracy ±0.2 Vol. %
Reaction time t90 Approx. 40 s